Our inspection includes:
Check the appliances and pipework for gas tightness
Check the standing and working pressure if test points are available
Check the burner pressure/gas rate against the manufacturer’s data plateCheck for the satisfactory provision of all necessary ventilation
Test the flue flow to ensure removal of products of combustion
Check the satisfactory operation of safety device
Check for physical stability, presence and effectiveness of brackets (where appropriate)
A full inspection of the entire chimney structure inspection and, where necessary, cleaning of the burner, combustion chamber, any injectors and heat exchanger
Inspection of ignition devices i.e. pilot lights and/or spark and flame sensing electrodes
Checking the integrity of all seals and gaskets
Ensure that any condensate traps and drains are free from debris
Checking the functionality of the expansion vessel including pressurising if required.
Testing the appliance in accordance with manufacturer’s instruction to ensure
The heat input and/or operating pressure are correct
The effectiveness of the flue
That all ventilation requirements are to current standards
The correct operation of all safety devices and that the boiler is safe for continuous use. A final combustion analysis and measurement against tolerances set by the manufacturer’s instructions
A test of any disturbed gas connections
Carry out functional testing of heating and hot water
A visual inspection of any other encountered gas appliances
Written notification of any gas safety defect which may affect the safe operation of your appliances
An assessment of your current heating controls and best practice advice regarding energy efficiency.
Investigate any evidence of unsafe operation
We will then issue your Landlord Gas Safety Certificate (or CP 12 Gas Safety Certificate), and you should provide a copy to your tenants.